■ Insulated roof systems or warm roofs as they are more commonly known, are a very good option for flat roof designs and are able to be utilised for new roof and re-roof construction.
■ The inclusion of a dedicated vapour barrier in the overall design is essential for controlling moisture that can permeate from the substrate.
■ Insulated roof systems are able to be fully adhered with approved adhesives or mechanically fixed with appropriate type tube washers and fixings.
■ The CNZ insulated boards are produced in the standard size of 2400mm x 1200mm. The thickness of the CNZ insulation board will determine the correct R-Value that has been nominated for the project.
■ The inclusion of a high density coverboard placed over the CNZ insulation board is essential and must be included in the overall design of the insulated roof system.
■ The choice of an appropriate membrane type must be considered in the overall insulated roof system.
■ Ensure the chosen substrate material has been installed to manufacture’s specification.
■ Install the vapour barrier directly to the chosen substrate to the manufacturer’s requirements.
■ Adhere the CNZ insulation boards to the fully adhered vapour barrier using a brick bond pattern.
■ Adhere the approved HD cover board at right angles to the adhered CNZ insulation board using a brick bond pattern.
■ Install the chosen membrane type to the manufacturer’s requirements to the fully adhered insulated roof system
components.
■ Ensure the chosen substrate material has been installed to manufacture’s specification.
■ Install the vapour barrier directly to the chosen substrate to the manufacturer’s requirements.
■ Place the CNZ insulation board to the fully adhered vapour barrier using a brick bond pattern.
■ Place the approved cover board at right angles to the CNZ insulation board using a brick bond pattern.
■ Mechanically fix the cover board and CNZ insulation board through to the substrate using an approved tube washer and appropriately sized fixing.
■ The amount of required fixings will be determined by the specified wind zone requirement for the project.
■ Consult the manufacturer of the supplied fixings for the correct required amount of fixings and position in relation to the insulated roof system components.
■ Install the chosen membrane type to the manufacturer’s requirements to the fully adhered insulated roof system components.