Merry Christmas! We are closed for the Holidays from 22nd Decembe
Merry Christmas! We are closed for the Holidays from 22nd Decembe
  • Home
  • ABOUT PIR
  • Products
    • Insulation Board
    • Profile Board
    • Accessories
    • ACE Wall
  • Fixing Details
    • DIRECT FIXING
    • FIXING TO BATTENS
    • FIXING BETWEEN STUDS
    • PROFILED CUT ROOF BOARD
    • INSULATED PRECAST SYSTEM
    • WARM ROOF SYSTEM
    • NEW ROOF
    • RETROFIT
    • CEILING
  • Gallery
  • FAQ
  • Documents
  • Contact Us
  • More
    • Home
    • ABOUT PIR
    • Products
      • Insulation Board
      • Profile Board
      • Accessories
      • ACE Wall
    • Fixing Details
      • DIRECT FIXING
      • FIXING TO BATTENS
      • FIXING BETWEEN STUDS
      • PROFILED CUT ROOF BOARD
      • INSULATED PRECAST SYSTEM
      • WARM ROOF SYSTEM
      • NEW ROOF
      • RETROFIT
      • CEILING
    • Gallery
    • FAQ
    • Documents
    • Contact Us
  • Home
  • ABOUT PIR
  • Products
    • Insulation Board
    • Profile Board
    • Accessories
    • ACE Wall
  • Fixing Details
    • DIRECT FIXING
    • FIXING TO BATTENS
    • FIXING BETWEEN STUDS
    • PROFILED CUT ROOF BOARD
    • INSULATED PRECAST SYSTEM
    • WARM ROOF SYSTEM
    • NEW ROOF
    • RETROFIT
    • CEILING
  • Gallery
  • FAQ
  • Documents
  • Contact Us

FIXING TO METAL OR TIMBER BATTENS

METAL BATTENS

■ If direct fixing is not possible due to uneven surface or the presence of mechanical services, the boards can be fixed to metal or timber battens.


■ Suitable metal battens or 50 x 25 mm timber battens are required at 600mm CRS. This will result in three rows of battens, lining up with the two edges and the centre of the boards. The battens are to be fixed to the soffit as per manufacturer’s recommendations 

TIMBER BATTENS

■ Use screws at a maximum of 300mm CRS to fix the boards to the furring metal battens. For timber battens use screws or nails at a maximum of 200mm CRS. The screws or nails must be in rows less than 600mm apart. Note: The substrate and fixing materials must be fit for purpose. Design loading on the board is not to exceed 0.375kPa for this fixing pattern. Additional fixings may be required when the boards are subjected to greater wind loads. Please contact CNZ Insulation for advice. 